ACSOON AF400M 400 Hz Static Frequency Converter
The ACSOON AF400M static frequency converter is designed for applications that require 400 Hz AC power from a 50 Hz or 60 Hz supply. The current product specification also lists an adjustable 40–500 Hz output option. Review the input, output, capacity and protection options below, then send your required voltage, phase and kVA for a configuration check. Read how a static frequency converter works for the operating principle.
Applications of ACSOON AF400M frequency converter
★Avionics AC product manufacture and test
★Aviation industry AC Power Test
★Submarines
★Vessel / ship for 400hz power
★Millitary equipment
★Electrical equipment on aircraft
Features and Characteristics
★ Galvanically Isolated output transformer, suitable for any unbalance loads, each single phase can be used independently.
★ Low harmonic distortion, pure sine wave, sinusoidal output.
★ Display real-time data:voltage, current, frequency and power.
★ Good performance on EMC, complied with EN61000-6-2:2005
★ Efficiency≥85%
★ GJB152A-97 Electromagnetic Emission and Susceptibility Requirements for Military Equipment and Subsystems
★ Complete protections (O/V, O/C, phase loss, over heat protections etc.)
★ Variable frequency and voltage adjustable
★ Display real-time data:voltage, current, frequency and power.
★ Robust cabinet housing & Compact size
★ Compatible with both 50Hz and 60Hz power supply network.
Technical Specifications
| Capacity | Single Phase Output: 1kVA, 2kVA, 3kVA, 5kVA, 10kVA, 15kVA, 20kVA, 30kVA, 45kVA, 60kVA, 100kVA, 150kVA,200kVA |
| Three Phase Output: 1kVA, 3kVA, 6kVA, 10kVA, 15kVA, 20kVA, 30kVA, 45kVA, 60kVA, 75kVA, 100kVA, 150kVA, 200kVA, 300kVA | |
| Input | Single Phase: 110Vac (L-N),120Vac (L-N), 220Vac (L-N), 230Vac (L-N) ±20%, or volt value as per customized. Split Phase also available |
| Three Phase: 200Vac (L-L),208Vac (L-L),380Vac (L-L), 400Vac (L-L), 415Vac (L-L) 440Vac (L-L)±20%. or volt value as per customized.3 Phase Delta or 3 Phase 4 Wire Wye type | |
| Frequency: 50/60/400Hz or 40hz - 70hz | |
| Output | Single Phase: 115Vac / 120Vac rated. 0-150Vac, 0-300Vac (L-N) adjustable,or volt value as per customized |
| Three Phase: 200Vac / 208Vac rated. 0-260Vac 0-520Vac (L-L) 3 Phase Delta or 3 Phase 4 Wire Wye type | |
| Frequency: 400Hz or 40-500Hz adjustable | |
| Circuit Breakers | with Input & Output MCCBs circuit breakers |
| Number of alternating current output | One output terminal strip, in which one ternimal strip must be installed inside of front panel door. If two output required, it could be in customized |
| Frequency regulation /stability | ≦0.1% |
| Voltage regulation / stability | +/-1% |
| Output VTHD | <3% @ Linnear load |
| Power Factor | ≧0.8 (Standard). Power Factor ≧ 0.9 (12 Pulse Optional). |
| Overall Efficiency | ≧85% |
|
Indication and
resolution
|
LED Digital frequency meter: 4 digits, resolution 0.1Hz |
| LED Digital voltmeter: 4 digits, resolution 0.1v | |
| LED Digital ammeter: 4-digit, resolution 0.1A | |
| LED Digital Watt meter: 4-digit, resolution 0.1kW | |
| Noise | <65db within one meter |
| Protection: | Protection: over/under voltage, over load over heat, short circuit and warning |
| Overload | 125% 30 seconds |
| Communicate protocol | Modbus mode RS232 / RS485 (Optional) |
| Cooling | Forced air |
| Mean Time Between Failure | 30,000H |
| Mean Time to Restoration | < 30 min |
| Working Temp. | -10℃ to 50℃ |
| Altitude | <1800m |
| EMC | complied with EN61000-6-2:2005 |
| Standard | GJB152A-97 Electromagnetic Emission and Susceptibility Requirements for Military Equipment and Subsystems |
Execution Of Acsoon® AF400M Static Frequency Converter: The system shall be housed in Sheet Steel cabinet with IP20 / IP32 /IP54 / IP55 protection and shall be powder coated in RAL7032 Grey shade. The cabinet shall be an upright, steel cabinet with removable side covers, The cooling fans shall be provided as per manufactures' standard. The cooling fans shall be provided as per manufactures' standard and hinge mounting front door. transformers are mounted on the bottom plate of the cabinet. The terminals for Mains Input & Output are provided on the interior side of the cabinet. Cable entry shall be provided from at the bottom side of the cabinet.
PS. Xi’an Jerrystar Instrument Co.,Ltd guarantees that your new electric equipment is warranted to be free from defects in workmanship and material for a period of one (1) years from date of shipment.During the warranty period.