| Capacity | 3kVA, 6kVA, 10kVA, 15kVA, 20kVA, 30kVA, 60kVA, 100kVA, 150Kva |
| Input | Three Phase: 200Vac (L-L),208Vac (L-L),380Vac (L-L), 400Vac (L-L), 415Vac (L-L) 440Vac (L-L)±20%. or volt value as per customized.3 Phase Delta or 3 Phase 4 Wire Wye type |
| Frequency: 40 - 70hz. | |
| Output Volt. | DC28.5VDC or 270VDC, voltage could be adjusted in a wide range. |
| Output Amperes. | 50A,100A, 200A, 300A, 400A, 500A, 600A, 800A, 1000A, 2000A |
| Voltage regulation / stability | +/-1% |
| Power Factor | ≧0.85 |
| Efficiency | ≧85% |
| Ripple | Less than 150mV, max 250mV (rms) |
| Display | VFD / LCD display, Volt. Amperes, and Power |
| Overload | 125% 10 min, 150% 60s, 200% 10s |
| Protection | O/V, under Voltage, current limiting, Over heating,Short Circuit Protections |
| Working Condition | Ambient Temp. -10℃ - 50℃ |
| Humidity: 10 - 95% | |
| Altitude < 1800 meters | |
| Standard | |
| Mean Time Between Failure | 30,000H |
| Mean Time to Restoration | < 30 min |
| Standard |
EN61000-6-2:2005 GJB152A-97 Electromagnetic Emission and Susceptibility Requirements for Military Equipment and Subsystems
MIL-STD-704F
|
The following table applies to the ADCW 28.5 V DC configurations in the Ver.25 export catalogue. Confirm a separate model datasheet for other output voltages mentioned in the original description, including 270 V DC.
| Item | Ver.25 catalogue data |
|---|---|
| Model example | ADCW-28600 |
| Nominal three-phase AC input | 208, 380, 400, 415, 440 or 480 V AC, depending on configuration |
| Input voltage tolerance | ±15% |
| Nominal input frequency | 50 or 60 Hz. Catalogue input frequency tolerance is 40–70 Hz. |
| Input power factor | ≥0.9 |
| Nominal DC output | 28.5 V DC |
| DC voltage adjustment | 20–32 V DC |
| Listed output current ratings | 300, 400, 500, 600, 800, 1,000 and 2,000 A |
| Voltage regulation | Line regulation ±0.5% FS. Load regulation ±1% FS. |
| Ripple and efficiency | Ripple ≤0.25 V. Overall efficiency ≥93%. |
| Display and communications | 0.1 V and 0.1 A display resolution. RS232 / RS485 with Modbus protocol. |
| Overload rating and duration | 125% for 10 min, 150% for 60 s and 200% for 30 s |
| Enclosure and operating environment | IP20, IP21 or IP54 according to configuration. Catalogue operating temperature −20 to 50 °C and humidity 10–95%. |