| Capacity | Three Phase Output: 30kVA, 45kVA, 60kVA, 90kVA, 100kVA, 120kVA, 150kVA, 180kVA,270kVA | |
| Input | Three Phase: 200Vac (L-L),208Vac (L-L),380Vac (L-L), 400Vac (L-L), 415Vac (L-L) 440Vac (L-L)±20%. or volt value as per customized.3 Phase Delta or 3 Phase 4 Wire Wye type | |
| Frequency: 40 - 70hz. | ||
| Output | Three Phase: 200Vac / 208Vac rated. 0-260Vac 0-520Vac (L-L) 3 Phase Delta or 3 Phase 4 Wire Wye type | |
| Frequency: 400Hz rated, 300Hz - 500hz adjustabed | ||
| Circuit Breakers | Installed with MCCB circuit breaker | |
| Number of alternating current output | One output terminal strip, in which one ternimal strip must be installed. two AC output could be in customized. Come with Aircraft Plug for the GPU with Trolley | |
| Number of DC output | Available on Combi GPU. deliver 28V DC power supply | |
| Frequency regulation /stability | ≦0.1% | |
| Voltage regulation / stability | +/-1% | |
| Output VTHD | <2% | |
| Power Factor | ≧0.8 (Standard). Power Factor ≧ 0.9 (12 Pulse Optional). | |
| Overall Efficiency | ≧85% | |
|
Displaying
|
LCD displaying, indications of voltage, current, and frequency value, with On / Off buttons | |
| Noise | <65db within one meter | |
| Protection |
Input short phase, Over/under voltage, Output A-phase over current, output B-phase overcurrent, output C-phase overcurrent, Short circuit protection & Overheat protection
|
|
| Communication protocol: | Modbus RS485 | |
| Crest | 1.414±0.1 | |
| Irush Current | Non soft start | |
| Overload | 125% 10mins, 150% 60s, 200% 30secs and 400% 1s | |
| Mean Time Between Failure | 30,000H | |
| Mean Time to Restoration | < 30 min | |
| Insulation resistance: | 500Vdc above 20MΩ | |
| Withstand voltage insulation | 1800Vac/5Ma/1 min | |
| Altitude | <1800m |
The Ver.25 export catalogue lists GPU400 400 Hz AC configurations for aircraft ground testing and maintenance in hangars and on aprons, with cabinet and trolley configurations shown. This table applies to the GPU400 catalogue configurations. Confirm the exact SKU and its ratings for other configurations described above.
| Item | Ver.25 catalogue data |
|---|---|
| Model examples | GPU400-330090T and GPU400-330090C |
| Nominal three-phase AC input | 208, 380, 400, 415, 440 or 480 V AC, depending on configuration |
| Input voltage tolerance | ±15% |
| Nominal input frequency | 50 or 60 Hz. Catalogue input frequency tolerance is 40–70 Hz. |
| Input power factor | ≥0.9 |
| Nominal AC output | 115 V (L–N) / 200 V (L–L) or 120 V (L–N) / 208 V (L–L), three-phase four-wire |
| Listed AC capacities | 30, 45, 60, 90, 120 and 180 kVA |
| Output voltage adjustment | 100–130 V (L–N) |
| Nominal output frequency | 400 Hz. Optional adjustable range 320–480 Hz. |
| Output stability | Frequency stability ±0.01% FS. Voltage regulation and stability ±1% FS. |
| Waveform and efficiency | Sine-wave output. VTHD <2%. Overall efficiency ≥93%. |
| Overload rating and duration | 125% for 10 min, 150% for 60 s and 200% for 30 s |
| Enclosure and operating environment | IP20, IP21 or IP54 according to configuration. Catalogue operating temperature −20 to 50 °C and humidity 10–95%. |
The catalogue shows a 28.5 V DC / 600 A Combi option. Confirm the AC/DC duty, whether both outputs are needed at the same time, and the supplied cables and connectors for the selected SKU.
For an enquiry, include the aircraft, application, input supply, required AC output and kVA, preferred mounting, and cable and connector requirements. Request a GPU400 quote.